Echo Point

High Temp Wireless Monitoring

Echo Point is Cosasco’s newest technology that pushes the boundaries of wireless ultrasonic monitoring. Ultrasonic transducers powered by off-the-shelf batteries communicate using WirelessHART to compatible gateways. An integrated thermocouple with a temperature correction algorithm provides high-accuracy measurements.

Up to 3x
More sensitive
Thru-Coating Technology
No coating removal
5-Year Battery Life
with 2 readings/day
932°F (500°C)
to -40°F (70°C)

Speak to an Echo Point Expert

Remove the guesswork and make better, data-driven decisions about your critical assets with Echo Point.

Thank you for your interest in Echo Point.
An expert will be in touch with you shortly.
Oops! Something went wrong while submitting the form.

Echo Point Features & Benefits

Three transducer choices for maximum flexibility

Thru-Coating is perfect for applications where coating removal is not an option.

High Sensitivity Duals are ideal for monitoring identified volumetric defects for maximum thin-wall sensitivity.

Ultra-High Temp has specialized coupling technology to monitor the hottest processes.

Certifications

Communication & Integration

Echo Point uses WirelessHART to communicate directly with certified gateways to Cosasco Data Online. Cosasco Data Online supports back-end communication via HART-IP, Modbus TCP/IP, or OPC to DCS and SCADA systems. Echo Point integrates with Cosasco Data Online to offer advanced analytics and seamlessly integrates with other Cosasco devices.

Wireless Transmitter

Each Echo Point Sensor is fully wireless and configured to collect readings at a user-defined interval (default is every 12 hours). Devices connect to compatible WirelessHART network gateways. Batteries are designed to run for five years and are replaceable with off-the-shelf lithium batteries.

Mounting

The sensor node attaches easily to the component’s outer surface with clamps or a magnetic base and can be modified for lower profile requirements

Transducer

Three transducer choices are available for maximum flexibility in options. All transducers are designed with a minimum high temperature of 275°F (135°C) and Ultra-High Temp has a maximum of 932°F (500°C).

Specifications

High Temperature & Ultra High Temperature Transducer Specifications
Thru-Coating
High Sensitivity Dual
Ultra-High Temp
Probe surface temperature
-20°F (-20°C) up to 275°F (135°C)
-20°F (-20°C) up to 275°F (135°C)
-40°F (-40°C) up to 932°F (500°C)
Transmitter temperature
-40°F (-40°C) up to 158°F (70°C)
-40° (-40°C) up to 158°F (70°C)
-40°F (-40°C) up to 158°F (70°C)
Measurement range
0.125" to 1.00" (3-25mm)
0.040" to 6" (1-150mm)
0.125" to 1.00" (3-25mm)
Measurement resolution
0.001" (0.025mm)
0.001" (0.025mm)
0.001" (0.025mm)
Thru-Coating
Yes*
No
No
Min. pipe diameter
2" NPS
2" NPS
2" NPS
Resolution
0.001" (0.025mm)
0.001" (0.025mm)
0.001" (0.025mm)
Element(s)
Dual
Dual
Single (delay-line)

* External FBE and homogenous PU/PE/PP coatings

⤓ Data Sheet

Case Studies

Coming soon.