Product Name |
Product Description |
|

|
8012/8022 CORRATER® Retractable Two-Electrode Probe ( 86 products ) |
These Models are ideal for direct mounting into plant pipework or vessels and allow insertion or removal while under system pressure. The electrode seals are suitable for all pH ranges. These probes employ two replaceable, identical electrodes which ar...
|
 |

|
6080 CORRATER® Retrievable High Pressure Two-Electrode Probe ( 200 products ) |
This probe employs two identical electrodes which are mounted at the end of the probe by threaded, insulated, glass-sealed studs. The glass seals provide high pressure integrity. The probe is sealed into the hollow plug of the access fitting with a cer...
|
 |

|
CORRATER® and CORROTEMP® CORRATER® Probe Accessories ( 214 products ) |
CORRATER® and CORROTEMP® CORRATER® probes are designed for safe installation and operation in various environments. Where danger of blowout exists, use of an appropriate safety device should be considered mandatory. This equipment is design...
|
 |

|
CORRATER® Probe Selection Guide
|
CORRATER® probes and instruments provide a direct measure of corrosion rate and a qualitative pitting tendency of metals in electrolytes by the technique of linear polarization resistance. CORRATER® systems have the particular advantage of fast...
|

|

|
Corrater Corrosion Monitoring By-Pass Rack ( 2 products ) |
Corrosion Monitoring By-Pass Racks are commonly used in industrial water treatment systems to determine the corrosive properties of potable - process - or cooling water. The By-Pass Rack creates a side stream off the main system in which corrosion test...
|
 |

|
CORROTEMP® Dual Sensor CORRATER® Probes
|
Temperature is one of the most important controllable factors affecting corrosion rate, particularly in refineries, chemical and petrochemical process plants. A rule of thumb is that corrosion rates double for each 10ºC temperature rise. The abili...
|

|

|
800 LPR Corrosion Rate Monitoring in Concrete with CORRATER® Probes ( 19 products ) |
The steel reinforcement in concrete structures is susceptible to corrosion when chloride ions enter into the concrete from de-icing salts applied to the concrete surface, or from seawater in marine environments. If chlorides are present in sufficient q...
|
 |

|
850 Corrater® LPR Soil Corrosion Rate Monitor ( 4 products ) |
Corrosion of underground pipelines costs the oil & gas industry millions of dollars each year. Due to more recent safety regulations enforced by the government, pipeline operators are coming under great pressure to provide enhanced protection of pi...
|
 |

|
900 Concrete Multi-Depth Sensor ( 17 products ) |
The steel reinforcement in concrete structures is susceptible to corrosion when chloride ions enter into the concrete from de-icing salts applied to the concrete surface, or from seawater in marine environments. If chlorides are present in sufficient q...
|
 |

|
6112 CORRATER® Laboratory LPR Probe ( 66 products ) |
This model is ideally suited for laboratory testing or light duty plant operations in a bypass rack where removal under system pressure is not required. For heavier duty plant operation see Model 7012 or 7022. This probe employs two replaceable identic...
|
 |

|
7012/7022 CORRATER® Two-Electrode LPR Probe ( 56 products ) |
The Model 7012/7022 provides a more rugged construction and is ideal for plant use in a bypass rack where removal under pressure is not required. This probe employs two replaceable, identical electrodes which are mounted at the end of the probe by thre...
|
 |

|
7212/7222 CORRATER® Two-Electrode LPR Probe ( 28 products ) |
This probe employs two identical electrodes which are mounted at the end of the probe by threaded, insulated studs. The glass reinforced epoxy electrode header used on the Model 7212 provides insulation and is preferred at high pH ranges over the glass...
|
 |